4.2.7 HA-G20BAT
The following table explains electrical performances on the Battery Packs (HA-G20BAT,
HA-G20BAT-CN).
Table 4.15
Item Specification Remark / Condition
Anti-static strength
Malfunction 6 KV (contact) / 8KV (in air)
Destruction 12 KV (contact, in air)
4.2.8 AD-S42120B
Table 4.16 explains electrical performance on the AC Adaptors (AD-S42120B, AD-S42120B-CN).
Table 4.16
Item Specification Remark / Condition
Withstanding noise
Surge Line to line: ±1KV (Peak)
Line to earth (ground): ±2KV (Peak)
- IEC61000-4-5
±4 KV (direct contact)
Anti-static strength
(ESD)
±8 KV (direct contact)
- IEC61000-4-2