SERVICE MANUALELECTRONIC CASH REGISTERSE-G1/PCR-T273/SM-T274(EX-256)JAN. 2013Ver.1 : Jun. 2013
SE-G1/PCR-T273/SM-T274– 8 –C-5. Loosen the nut and disconnect the ground wire.C-6. Disconnect the DRAWER connector.C-7. Remove the COVER/PCB.Connec
SE-G1/PCR-T273/SM-T274–9–D. AC-ADAPTORD-1. Undotwoscrews.(M-typeonly)Screws(S3)D-2. Disconnect one connector.D-3. RemovethePS-ASSY.Connec
SE-G1/PCR-T273/SM-T274–10–NOTES ON ASSEMBLYWhentheAC-ADAPTORisreplacedwithanewpart,attachthecabletieandtape.Cable tie TapeE. ASSY/MOT
SE-G1/PCR-T273/SM-T274–11–F. DISPLAY UNITF-1. Undo four screws.F-2. Peel off the tape and then disengage the FFC.FFC TapeScrews(S7)F-3. Remove
SE-G1/PCR-T273/SM-T274–12–F-4. Disengage two hooks and then remove the FRAME/DISPLAY.HooksFRAME/DISPLAY
SE-G1/PCR-T273/SM-T274–13–G. PCB ASSY/E256-1G-1. Disconnect one connector and two FFC.G-2. Undo two screws.FFCConnectorFFCScrews(S4)G-3. Remove
SE-G1/PCR-T273/SM-T274–14–H. MOUNT/PCBH-1. Undo three screws.H-2. Remove the MOUNT/PCB.Screws(S4)Screw(S3)MOUNT/PCBI. KEY-BOARD-ASSYI-1. Undo
SE-G1/PCR-T273/SM-T274–15–J. PRINTERJ-1. Undo one screw.J-2. Remove the PRINTER.Screw(S3) PRINTERNOTE: The PLATEN ARM must be open to remove th
SE-G1/PCR-T273/SM-T274– 16 –4. DIAGNOSTIC PROGRAM4-1. Launching The Diagnostic ProgramNOTE: If a receipt has been issued in other modes, the Diagno
SE-G1/PCR-T273/SM-T274– 17 –4-3. Notes For The Diagnostic Program• To forcibly terminate a test, press y key or turn the Mode Switch to [OFF].If a t
SE-G1/PCR-T273/SM-T274CONTENTS1. SPECIFICATIONS ...
SE-G1/PCR-T273/SM-T274– 18 –4-5. Operation Of Each Test[1] Status Display[Function]The device status is indicated with ON/OFF of the segment.[Displa
SE-G1/PCR-T273/SM-T274– 19 –[2] Batch Test[Function]Display, ROM, printer, time setting, drawer and buzzer tests are performed continuously.[Operatio
SE-G1/PCR-T273/SM-T274– 20 –[3] Internal ROM Check SUM Test[Function]Performs the ROM check sum test.[Operation]Command : n 5 1 8 kn: Number of tim
SE-G1/PCR-T273/SM-T274– 21 –[5] Internal Printer Character Print Test[Function]Tests if the internal printer prints characters correctly.[Operation]C
SE-G1/PCR-T273/SM-T274– 22 –[6] Time Setting/Time Display[Function]Allows you to check or change the time (hour, minutes, seconds) and date (year, mo
SE-G1/PCR-T273/SM-T274– 23 –[7] Drawer Open Test[Function]Tests whether drawers operate correctly. The drawer sensor checks every two seconds while t
SE-G1/PCR-T273/SM-T274– 24 –[9] Key Test[Function]Tests if keys are recognized correctly. Each key is assigned with a hard key code. This test checks
SE-G1/PCR-T273/SM-T274– 25 –5. PCB LAYOUT5-1. E256-1 PCB
SE-G1/PCR-T273/SM-T274– 26 –5-2. E256-E2 PCB
SE-G1/PCR-T273/SM-T274– 27 –6. EXPLODED VIEW/PARTS LISTMODEL : SE-G1/PCR-T723/SM-T274(EX-256)<CONTENTS>6-1. EXPLODE VIEW ...
SE-G1/PCR-T273/SM-T274– 1 –1. SPECIFICATIONS1-1. Electrical SpecicationsPower ConsumptionIn operation Max.100 V 120 V 220 V 230 V 240 V122 mA 111 m
SE-G1/PCR-T273/SM-T274– 28 –6-1. EXPLODED VIEWFINAL-ASSYS-type M-typeEU &UK onlyMAIN-UNITDL-2816DL-2817MAIN-UNITDL-1335DL-1844DL-1845135786429111
SE-G1/PCR-T273/SM-T274– 29 –MAIN-UNITKEY-BOARD-ASSYDISPLAYPCB ASSY/E256-1FUSES-typeM-type263233273534171823302928312419404649505147483639383720252221S
SE-G1/PCR-T273/SM-T274– 30 –6-2. PARTS LIST 1 SE-G1SB 2 SE-G1SD 3 SE-G1SG 4 SE-G1SA 5 SE-G1SK 6 SE-G1T 7 SE-G1MB 8 SE-G1MG 9 SE-G1MA 10 SE-
SE-G1/PCR-T273/SM-T274– 31 – 1 SE-G1SB 2 SE-G1SD 3 SE-G1SG 4 SE-G1SA 5 SE-G1SK 6 SE-G1T 7 SE-G1MB 8 SE-G1MG 9 SE-G1MA 10 SE-G1MK11 PCR-T2731
SE-G1/PCR-T273/SM-T274– 32 – 1 SE-G1SB 2 SE-G1SD 3 SE-G1SG 4 SE-G1SA 5 SE-G1SK 6 SE-G1T 7 SE-G1MB 8 SE-G1MG 9 SE-G1MA 10 SE-G1MK11 PCR-T2731
SE-G1/PCR-T273/SM-T274– 33 –6-3. DRAWER S-type (DL-1335/1844/1845)EXPLODED VIEWDL-1335DL-1844/184531920101617318156W1W1479S1S12836615 151113121414S2S
SE-G1/PCR-T273/SM-T274– 34 –PARTS LIST1 DL-13352 DL-18443 DL-18451231 10449184 CASE/MAIN/BK RJE504018-001V01 1 1 B1 10449188 CASE/MAIN/WE RJE504018-00
SE-G1/PCR-T273/SM-T274– 35 –6-4. DRAWER M-type (DL-2816/2817)EXPLODED VIEW163S1S1S2117S18S16994N1N2N151012S3151311422W2W2S3S6102W120S4S4S419212223171
SE-G1/PCR-T273/SM-T274– 36 –PARTS LIST1 DL-28162 DL-281712N 1 10445372 CASE/MAIN RJE502983-002V02 1 BN 1 10447862 CASE/MAIN RJE502983-003V02 1 B2 5500
CASIO COMPUTER CO., LTD.CS Technical DepartmentTOKYO, JAPANVer.1 : Jun. 2013 •CorrectionoftheEXPLODEDVIEW(P33) •CorrectionofthePARTSLIST
SE-G1/PCR-T273/SM-T274– 2 –2. INITIALIZATION(1) Remove the memory protection batteries.Memory protection batteries(2) If the Power cord is plugged
SE-G1/PCR-T273/SM-T274– 3 –3. DISASSEMBLY3-1. Important• Please note that the product on this manual may appear to be different from the actual one
SE-G1/PCR-T273/SM-T274– 4 –3-2. FlowchartSeetheowchartbelowfortheorderofdisassemblingmajorcomponents.B. MAIN-UNIT S-typeD. AC-ADAPTORF. DI
SE-G1/PCR-T273/SM-T274– 5 –B. MAIN-UNIT S-typeB-1. Remove the cable tie.B-2. Pull the drawer release lever and then remove the drawer.NOTE: In cas
SE-G1/PCR-T273/SM-T274– 6 –B-5. Disconnect the DRAWER connector.ConnectorNOTES ON ASSEMBLYHook the DRAWER cable on the hook.B-6. Undo three screws a
SE-G1/PCR-T273/SM-T274– 7 –C. MAIN-UNIT M-typeC-1. Remove the cable tie.C-2. Pull the drawer release lever and then remove the drawer.NOTE: In cas